chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

With Plastic Collar|Page 5917 > < With Plastic Collar|Page 5915
Page 1
background image

Quick-Connect Fittings: Service and Repair
With Metal Collar

Tools Required

-

J 37088 Tool Set, Fuel Line Quick-Connect Separator

WARNINGS: 

-

Wear safety glasses when using compressed air, as flying dirt particles may cause eye injury.

-

Relieve the fuel system pressure before servicing fuel system components in order to reduce the risk of fire and personal injury.

-

After relieving the system pressure, a small amount of fuel may be released when servicing the fuel lines or connections. In order to
reduce the chance of personal injury, cover the regulator and the fuel line fittings with a shop towel before disconnecting. This will catch
any fuel that may leak out. Place the towel in an approved container when the disconnection is complete.

CAUTIONS: 

-

Before attempting any On-Vehicle Service, place a dry chemical (Class B) fire extinguisher near work area.

-

Cap the fittings and plug the holes when servicing the fuel system in order to prevent dirt and other contaminants from entering the open pipes and
passages.

-

Always maintain cleanliness when servicing fuel system components.

REMOVAL PROCEDURE

1. Relieve the fuel system pressure. Refer to Fuel Pressure Release Procedure.
2. If plastic collar quick connect fittings are used, Refer to Quick Connect Filling(s) Service (Plastic Collar) for the correct service procedure. 

3. Grasp both sides of the fitting. Twist the female connector 1/4 turn in each direction to loosen any dirt within the fitting.

4. Blow dirt out of the fitting using compressed air.

5. Choose the correct tool from J 37088 Tool Set for the size of the fitting. Insert the tool into the female connector, then push inward to release the

locking tabs.

With Plastic Collar|Page 5917 > < With Plastic Collar|Page 5915