Page 7
background image

4. Install the evaporator and blower module assembly cover (2) to evaporator case (3).

Notice:  Refer to Fastener Notice.

5. Secure cover with the fourteen screws (1).

Tighten the screws to 1.9 N.m (17 lb in).

6. Install new sealing washers to the evaporator inlet and outlet tubes.

7. Install the evaporator inlet tube (4) to the evaporator (5).
8. Install the evaporator inlet tube retaining nut (3).

Tighten the nut to 16 N.m (12 lb ft).

9. Install the evaporator outlet hose and retaining nuts (4,5).

Tighten the nut to 18 N.m (13 lb ft).

10. Connect the low pressure sensor electrical connector.
11. Connect the blower motor electrical connector.