chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Air Duct > < Air Temperature Actuator Replacement|Page 7163
Page 3
background image

5. Install the evaporator inlet tube (4) to the evaporator (5).
6. Install the evaporator inlet tube retaining nut (3).

Tighten
Tighten the nut to 16 N.m (12 lb ft).

7. Install the evaporator outlet hose and retaining nuts (4,5).

Tighten
Tighten the nut to 18 N.m (13 lb ft).

8. Connect the low pressure sensor electrical connector.
9. Connect the blower motor electrical connector.

10. Connect the blower motor resistor assembly electrical connector.
11. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
12. Leak test the fittings of the repaired or replaced component using the J 39400-A.

Air Duct > < Air Temperature Actuator Replacement|Page 7163