Page 7
background image

14. Connect the blower motor assembly electrical connector.

15. Connect the low pressure sensor electrical connector (2).
16. Install the coolant recovery reservoir.
17. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
18. Leak test the fittings of the components using the J 39400-A.