chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Air Temperature Actuator Replacement|Page 13899 > < Air Temperature Actuator Replacement|Page 13897
Page 5
background image

9. Remove the screws (2) from the evaporator and blower module assembly.

10. Remove the evaporator and blower module assembly front cover (3).
11. Remove the recirculation door actuator (7) and the linkage.

Installation Procedure

1. Install the recirculation door actuator (7) and the linkage.
2. Install the evaporator and blower module assembly cover (3).

Notice:  Refer to Fastener Notice.

 

3. Install the screws.

Tighten the screws to 1.9 N.m (17 lb in).

4. Install new sealing washers to the evaporator inlet and outlet tubes.

5. Install the evaporator inlet tube (4) to the evaporator (5).
6. Install the evaporator inlet tube retaining nut (3).

Tighten the nut to 16 N.m (12 lb ft).

7. Install the evaporator outlet hose and retaining nuts (4,5).

Tighten the nut to 18 N.m (13 lb ft).

Air Temperature Actuator Replacement|Page 13899 > < Air Temperature Actuator Replacement|Page 13897