7. Install the evaporator inlet tube (4) to the evaporator (5).
8. Install the evaporator inlet tube retaining nut (3) and tighten to 16 Nm (12 lb ft).

9. Install the evaporator outlet hose and retaining nuts (4,5) and tighten to 18 Nm (13 lb ft).

10. Connect the low pressure sensor electrical connector.
11. Connect the blower motor electrical connector.
12. Connect the blower motor resistor assembly electrical connector.
13. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging   (See: Service and Repair/Refrigerant Recovery and

Recharging).

14. Leak test the fittings of the repaired or replaced component using the J 39400-A.
15. Install the battery. Refer to Battery Replacement (Primary)   (See: Starting and Charging/Battery/Service and Repair/Removal and Replacement).