chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

A/C Coupler O-ring|Service Precautions|Page 9917 > < A/C System|Page 9912
Page 1
background image

A/C Coupler O-ring: Service Precautions

Install new GM-approved service replacement air conditioning O-rings when a joint or a fitting is installed, except when the O-rings are provided on new
replacement components. Unless service replacement O-rings of the specified part numbers are used, excessive leakage of Refrigerant-134a may occur.
Refer to the part number for identification, not to the former color-coating method of identification, because some formerly color-coated service
replacement O-rings may be black.

Air conditioning O-rings should be coated with mineral base 525 viscosity refrigerant oil just before installation and should be slipped onto the flange
tube to assure proper locating and sealing. To prevent the possibility of swelling and a reduction in sealing effectiveness, O-rings should not be allowed
to soak in refrigerant oil. Before installation, the O-rings and the fittings should be examined to insure that they have not been nicked or deformed.
Nicked or deformed parts must be replaced or excessive refrigerant leakage may result.

A/C Coupler O-ring|Service Precautions|Page 9917 > < A/C System|Page 9912