chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Heated Oxygen Sensor (HO2S 1) Testing|Page 1166 > < Heated Oxygen Sensor (HO2S 1) Testing
Page 2
background image

The catalyst monitor sensors operate the same as the fuel control sensors. Although the Bank 1 Sensor 2 and Bank 1 Sensor 3 sensors main
function is catalyst monitoring, they also play a limited role in fuel control. If a sensor output indicates a voltage either above or below the 450
millivolt bias voltage for an extended period of time, the VCM will make a slight adjustment to fuel trim to ensure that fuel delivery is correct for
catalyst monitoring.

Refer to System Diagnosis / Diagnostic Charts for testing information. See: Powertrain Management/Computers and Control Systems/Testing
and Inspection

Heated Oxygen Sensor (HO2S 1) Testing|Page 1166 > < Heated Oxygen Sensor (HO2S 1) Testing