Oxygen Sensor > < Diagram Information and Instructions|Page 816
Page 2
background image

MAP Sensor Circuit (PCM)

Circuit Description:

The Manifold Absolute Pressure (MAP) sensor measures the changes in the intake manifold pressure which result from engine load (intake
manifold vacuum) and rpm changes; and converts these into a voltage output. The control module sends a 5 volt reference voltage to the MAP
sensor. As the manifold pressure changes, the output voltage of the sensor also changes. By monitoring the sensor output voltage, the control
module knows the manifold pressure. At lower pressure output voltage will be about 1 to 2 volts. While at higher pressure or at Wide Open
Throttle (WOT) output voltage will be about 4 to 4.8 volts.The MAP sensor is also used, under certain conditions, to measure barometric pressure,
allowing the control module to make adjustments for different altitudes. The control module uses the MAP sensor to control fuel delivery and
ignition timing.

Test Description:

Numbers below refer to circled numbers on the diagnostic chart.

Important

^

Be sure to use the same diagnostic test equipment for all measurements.

1. Checks MAP sensor output voltage to the control module. This voltage, without engine running, represents a barometer reading to the control

module.

^

When comparing Tech 1 "Scan" readings to a known good vehicle, it is important to compare vehicles that use a MAP sensor having the
same color insert or having the same "Hot Stamped" number.

2. Applying 34 kPa (10" Hg) vacuum to the MAP sensor should cause the voltage to change. Subtract second reading from the first. Voltage

value should be greater than 1.5 volts. Upon applying vacuum to the sensor, the change in voltage should be instantaneous. A slow voltage
change indicated a faulty sensor.

3. Check vacuum hose to sensor for leaking or restriction. Be sure that no other vacuum devices are connected to the MAP hose.

NOTE: Make sure electrical connector remains securely fastened.

4. Disconnect sensor from bracket and twist sensor by hand (only) to check for intermittent connection. Output changes greater than .1 volt

indicates a bad connector or connection. If OK replace sensor.

Oxygen Sensor > < Diagram Information and Instructions|Page 816