chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Air Cleaner Housing > < Curb Idle
Page 1
background image

Idle Speed: Adjustments
Fast Idle

Idle Speed Adjustment Location

1. Set the parking brake and block the drive wheels
2. Engine must be at normal operating temperature with the air cleaner on and all accessories turned off
3. Install J 26925 Tachometer or equivalent
4. Remove the connector from the fast idle solenoid
5. Connect an insulated jumper wire from the battery positive (+) terminal to the solenoid terminal. This will energize the solenoid
6. Open the throttle momentarily to energize and fully extend the fast idle solenoid plunger
7. Adjust the extended plunger by turning the hex head to obtain the fast idle speed shown on the emission control information label
8. Remove the jumper wire and install the connector to the fast idle solenoid

Air Cleaner Housing > < Curb Idle