G 20 Van V8-5.7L VIN R (1996)
Oxygen Sensor: Testing and Inspection
Heated Oxygen Sensor (HO2S 1) Testing
The heated oxygen sensor circuit, if open, should set a Diagnostic Trouble Code (DTC) P0134 and the Scan tool will display a constant voltage between
350-550 mV. A constant voltage below 250 mV in the sensor circuit should set DTC P0131, while a constant voltage above 750 mV in the circuit should
set DTC P0132. DTC P0131 and DTC P0132 could also be set as a result of fuel system problems. Refer to DTC P0131 HO2S Circuit Low Voltage
Bank 1 Sensor 1 or DTC P0132 HO2S Circuit High Voltage Bank 1 Sensor 1 or DTC P0134 HO2S Insufficient Activity Bank 1 Sensor 1. Refer
to System Diagnosis / Diagnostic Tables for testing information. See: Powertrain Management/Computers and Control Systems/Testing and Inspection