chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Deployed Inflator Module|Page 10423 > < Deployed Inflator Module|Page 10421
Page 2
background image

^

Wear safety glasses throughout the procedures.

^

Make sure the area around the inflator module is clear of all people and loose or flammable objects.

^

Short the deployment harness wires as instructed.

^

Connect the deployment harness to the inflator module before you connect it to the power source.

^

Connect the deployment harness to the power source to immediately deploy the air bag.

Failure to follow the procedures In the order listed may result in personal injury.

Figure 27

Figure 28

Figure 29

16. Disconnect the inflatable restraint I/P module, yellow 2-way connector. This connector is located behind the passenger knee bolster.
17. Cut the inflatable restraint I/P module harness connector from the vehicle. Leave at least 160 mm (6 inches) of wire at the connector (Figure 30).
18. Strip 13 mm (0.5 inch) of insulation from each wire lead of the connector (Figure 30).
19. Cut two 6.1 m (20 feet) deployment wires from 0.8 mm2 (18 gauge) or thicker multi-strand wire. Use these wires to fabricate the passenger

deployment harness.

20. Strip 13 mm (0.5 inch) of insulation from both ends of the wires cut in the previous step.
21. Short the wires by twisting together one end of each (Figure 31). The deployment wires shall remain shorted and not connected to a power source

until you are ready to deploy the air bag.

Deployed Inflator Module|Page 10423 > < Deployed Inflator Module|Page 10421