Brake Bleeding: Service and Repair
Hydraulic System Bleeding

With ABS System

Fig. 59  EHCU/BPMV Module Bleeding

MANUAL BLEEDING

The Electro-Hydraulic Control Unit Brake Pressure Modulator Valve Module (EHCU/BPMV) should be bled after replacement or if air is
trapped in the unit or system. If system bleeding is required, the module must be bled thoroughly before the wheel cylinders and calipers.

There are two bleeders on top of the unit that appear to be normal bleeders (figure 221). These are modulator bleeders and must remain closed
when the unit is not pressurized.

The internal bleeders are on either side of EHCU/BPMV module. The valves are used to open the internal passages within the EHCU/BPMV
module. Both bleed valves must be rotated 1/4 to 1/2 turn counterclockwise before beginning the bleed process. The valve on the lefthand side is
used for the rear brakes and the valve on the righthand side is used for the front brakes.

NOTE: The ignition switch must be in the Off position or false diagnostic trouble codes may be stored.

SPECIAL TOOL REQUIRED (or equivalent)

^

J-39177, Combination valve pressure bleeding tool (three required).

PROCEDURE

1. Install combination valve depressor tool J-39177 to LH high pressure accumulator bleed stem of EHCU/BPMV module.
2. Install combination valve depressor tool J-39177 to RH high pressure accumulator bleed stem of EHCU/BPMV module.
3. Install combination valve depressor tool J-39177 to rear combination valve.
4. Ensure master cylinder fluid level, fill if required.
5. Bleed EHCU/BPMV module as follows:

a. Slowly depress brake pedal one time and hold.
b. Open left modulator bleeder, until fluid flows clearly or pedal is depressed, the close left bleeder.
c. Slowly release brake pedal.
d. Wait 15 seconds, then repeat steps until all air is bled from EHCU/BPMV module.
e. Close LH internal bleed valve. Torque bleed valve to 7 Nm (5 ft lbs).
f.

Repeat preceding bleed steps for righthand bleed procedure.

g. Remove special tools.

6. Ensure master cylinder fluid level, fill if required.