Shift Solenoid Chart

DESCRIPTION

This electrical device is used to control fluid flow acting on the 2-3 shift valves. The solenoid is a normally open exhaust valve that is used with
the 1-2 shift solenoid to allow four different shifting combinations. The solenoid is attached to the control valve body within the transmission.

3-2 Shift Solenoid

3-2 Control Solenoid

DESCRIPTION

This electrical device is used to control fluid flow acting on the 3-2 shift valve, which then controls the 2-4 band apply rate and 3-4 clutch release
rate. It is a pulse width modulated solenoid that operates on a negative duty cycle. This solenoid controls the 3-2 downshift feel and is attached to
the control valve body within the transmission.