chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Expansion Valve|Service and Repair|Page 14278 > < Expansion Block/Orifice Tube|Service and Repair|Page 14274
Page 1
background image

Expansion Valve: Service and Repair

THERMAL EXPANSION VALVE REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.

2. Remove the evaporator tube to thermal expansion valve (TXV) nut (1).
3. Disconnect the evaporator outlet and inlet tube from the TXV.
4. Remove and discard the sealing washers.
5. Cap off the evaporator inlet and outlet tube.

IMPORTANT:  Cap or tape the open evaporator inlet and outlet tubes immediately to prevent contamination of the refrigerant system.

6. Remove the TXV to evaporator bolts.
7. Remove the TXV from the evaporator core.
8. Remove and discard the sealing washers.

INSTALLATION PROCEDURE

1. Install the new sealing washers onto the evaporator core.

Expansion Valve|Service and Repair|Page 14278 > < Expansion Block/Orifice Tube|Service and Repair|Page 14274