chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

A/C - Defroster Blows Cold Air During Remote Start|Page 15551 > < A/C - System Unable to Maintain Desired Temperature|Page 15546
Page 1
background image

Control Module HVAC: All Technical Service Bulletins
A/C - Defroster Blows Cold Air During Remote Start

Bulletin No.: 07-01-38-002

Date: May 18, 2007

TECHNICAL

Subject:

HVAC Defroster Blows Cold Air During Remote Start Event (Reprogram HVAC Control Module)

Models:
2007 Chevrolet Impala, Monte Carlo

with Single Zone HVAC System (RPO C67)

Condition

Some customers may comment that after using the remote start, the defroster blows cold air when its cold outside or warm air when its hot outside. It
appears to function the opposite of how it should.

Cause

This condition may be caused by a software anomaly within the HVAC control module.

Correction

A new calibration has been released to correct this condition. Reprogram the HVAC control module using SPS. This new service calibration is available
on TIS2WEB.

Warranty Information

For vehicles repaired under warranty, use the table.

Disclaimer

A/C - Defroster Blows Cold Air During Remote Start|Page 15551 > < A/C - System Unable to Maintain Desired Temperature|Page 15546