chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Campaign - Inspect/Replace Post-Catalyst O2 Sensor|Page 9384 > < Campaign - Inspect/Replace Post-Catalyst O2 Sensor
Page 2
background image

1.

Raise and support the vehicle. 

2.

Inspect the heated oxygen sensor bank 1 sensor 2 by pulling back the oxygen sensor protective sleeve (1). The wires should be the following
colors:

-

Delphi P/N 12570149 - Used on Model Year 2007, Brown (2), Purple (1) and Tan (1).

-

Denso P/N 12608662 - Used on Model Year 2008, Black (2), White (1), and Blue (1).

3.

If the inspection identifies that the vehicle was built with the incorrect sensor, replace bank 1 sensor 2 with the correct sensor as mentioned above.
Refer to step 5 for the sensor replacement procedure, if necessary.

4.

If the vehicle was built with the correct sensor, ensure that the protective sleeve is restored to its original position and lower the vehicle.

5.

Remove the connector position assurance (CPA) retainer.

6.

Disconnect the bank 1 sensor 2 electrical connector.

7.

Remove the sensor from the catalytic converter.

8.

Install the correct sensor as mentioned above to the catalytic converter.

Tighten

Tighten the sensor to 42 N.m (31 lb-ft).

9.

Connect the bank 1 sensor 2 electrical connector.

10.

Install the CPA retainer.

11.

Lower the vehicle.

Claim Information

For vehicles repaired under this service update, use the table.

Campaign - Inspect/Replace Post-Catalyst O2 Sensor|Page 9384 > < Campaign - Inspect/Replace Post-Catalyst O2 Sensor