K 10 P/U 4WD L6-292 4.8L (1985)
Blower Motor: Service and Repair
Fig. 5 Front blower motor & evaporator assembly. R & V Series
C, K, R & V SERIES
FRONT UNIT
1.
Disconnect battery ground cable, then remove insulator if equipped.
2.
Disconnect motor harness lead and ground wire, then remove motor cooling tube, Fig. 5.
3.
Remove blower to case mounting screws, then remove blower by carefully prying flange away from case.
4.
Remove cage from motor by removing shaft retaining nut.
5.
Reverse procedure to install. Replace sealer where needed.