6. Connect the reservoir assembly (1) to the pump housing assembly (2).
7. Install the O-ring seal.
8. Fastener Notice
Install the connector and fitting assembly (4) to the pump housing (1).
9. Install the pump mounting studs (2) to the pump housing (1).
Tighten
Tighten the pump mounting studs to 57.5 N.m (44 lb ft).
10. Tighten the connector and fitting assembly.
Tighten
Tighten the connector and fitting assembly to 75 N.m (55 lb ft).