Engine Control Module: Service and Repair
Vehicle Control Systems

Remote Procedure

The Remote SPS method is a three-step process that involves the following procedures:

1. Connecting the Tech 2 to the vehicle and obtaining the information from the module.
2. Connecting the Tech 2 to the terminal and downloading a new calibration file from the terminal into the Tech 2 memory.
3. Reconnecting the Tech 2 to the vehicle and uploading the new calibration file into the module.

Performing The Remote Procedure
1. Connect the Tech 2 to the vehicle and obtain the module information using the following procedure:

1.1.

Connect the Tech 2 to the vehicle data link connector (DLC), with the engine and the Tech 2 OFF.

IMPORTANT:  Ensure the control module is installed in the vehicle and the battery is fully charged before programming.

1.2.

Turn ON the Tech 2.

1.3.

Press Enter at the title screen.

1.4.

Turn ON the ignition, with the engine OFF.

1.5.

Select Service Programming System at the Main Menu.

1.6.

Select Request Info.

IMPORTANT:  Select Request Info Again if a vehicle identification number (VIN) was previously stored in the Tech 2.

1.7.

Enter the vehicle description by following the on-screen instructions.

1.8.

Turn OFF all accessories and select Continue.

1.9.

Verify that the correct VIN is entered on the Tech 2 and select Yes.

IMPORTANT:  Select No and write down the VIN if the VIN is incorrect.

2. Turn OFF the Tech 2.
3. Disconnect the Tech 2 from the vehicle.
4. Turn OFF the ignition.

Programming|Page 2275 > < Programming|Page 2273