chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Base Model|Page 9045 > < Ambient Temperature Sensor / Switch HVAC|Specifications|Page 9042
Page 1
background image

Ambient Temperature Sensor / Switch HVAC: Service and Repair
Base Model

AMBIENT AIR TEMPERATURE SENSOR REPLACEMENT BASE MODEL

REMOVAL PROCEDURE

CAUTION:  Before servicing any electrical component, the ignition key must be in the "OFF" or "LOCK" position and all electrical loads
must be "OFF", unless instructed otherwise in these procedures. If a tool or equipment could easily come in contact with a live exposed
electrical terminal, also disconnect the negative battery cable. Failure to follow these precautions may cause personal injury and/or damage
to the vehicle or its components.

1. Remove the negative battery cable. 
2. Remove the left and right park/turn signal lamp assemblies. 
3. Remove the screws from the radiator grille. 
4. Remove the radiator grille. 

 

5. Disconnect the electrical connector (2). 
6. Remove the outside air temperature sensor screw. 
7. Remove the outside air temperature sensor (1) from the vehicle. 

INSTALLATION PROCEDURE

1. Install the outside air temperature sensor (1) to the vehicle. 
2. Install the outside air temperature sensor screw. 
3. Connect the electrical connector (2). 
4. Install the radiator grille. 

NOTICE:  Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners
requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints,
lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping
force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts
and systems.

5. Install the radiator grille screws. 

TIGHTEN

-

Tighten the screws to 2 Nm (18 lb in).

Base Model|Page 9045 > < Ambient Temperature Sensor / Switch HVAC|Specifications|Page 9042