Distributor: Testing and Inspection

NOTICE:  Discoloration of the cap and some whitish build up around the cap terminals is normal. Yellowing of the rotor cap, darkening and some
carbon build-up under the rotor segment is normal. Replacement of the cap and rotor is not necessary unless there is a driveablity concern.

Inspect
1. Cap for cracks, tiny holes or carbon tracks between cap terminal traces. Carbon tracks can be diagnosed by using an ohmmeter. With the cap

removed, place one base ohmmeter lead on a cap terminal. Use the other lead to probe all other terminals and the center carbon ball. Move the
base lead to the next terminal and probe all other leads. Continue until all secondary terminals have been tested. If there are any non-infinite
readings, replace the cap.

2. Cap for excessive build up of corrosion on the terminals. Scrape them clean or replace the cap. Some build up is normal.

3. Rotor segment. Replace the rotor if there is excessive wear on the rotor segment or the plastic under the segment or staked post is melted. Some

looseness of the rotor segment is normal and does not cause performance problems.

4. Shaft for shaft-to-bushing looseness. Insert the shaft in the housing. If the shaft wobbles, replace the housing assembly.

5. Housing for cracks or damage.

^ Refer to Computers and Control Systems for ignition system diagnosis. See: Powertrain Management/Computers and Control Systems/Testing

and Inspection