chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Relays and Modules - Computers and Control Systems > < Diagram Information and Instructions|Page 4134
Page 1
background image

Oxygen Sensor: Service and Repair

Oxygen Sensor

NOTE:  

-

The Oxygen Sensor (O2S) has a permanently attached pig-tail and connector. This pig-tail should not be removed, since removal will affect proper
operation of the O2S.

-

Take care when handling the O2S. The in-line electrical connector and louvered end must be kept free of grease, dirt, or other contaminants. Also,
avoid using cleaning solvents of any type. Do not drop or roughly handle the O2S.

REMOVE OR DISCONNECT:

^

The O2S may be difficult to remove when engine temperature is below 48°C (120°F). Use caution, since excessive force may damage threads in
exhaust manifold or pipe.

-

Disconnect negative battery cable.

-

Disconnect electrical connector releasing locking tab.

-

Using suitable wrench, carefully back out sensor. 

INSTALL OR CONNECT:

IMPORTANT:
^

A special anti-seize compound is used on the 02S threads. The compound consists of liquid graphite and glass beads. The graphite will tend to
burn away, but the glass beads will remain, making the sensor easier to remove.

^

New, or service replacement sensors will already have the compound applied to the threads. If a sensor is removed from an engine, and if for
any reason it is to be reinstalled, the threads must have anti-seize compound applied before reinstallation.

-

Coat threads of 02S with anti-seize compound (GM P/N 5613695 or equivalent), if necessary.

-

Install and torque oxygen sensor to 41 Nm (30 lb.ft.).

-

Reconnect electrical connector.

-

Reconnect negative battery cable.

Relays and Modules - Computers and Control Systems > < Diagram Information and Instructions|Page 4134