chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Deployment Procedures|Page 12430 > < Deployment Procedures|Page 12428
Page 4
background image

Inflatable Restraint Instrument Panel Module Replacement

CAUTION:

^

Refer to SIR Caution in Service Precautions.

^

Refer to SIR Inflator Module Handling And Storage Caution in Service Precautions.

REMOVAL PROCEDURE

1. Remove upper IP trim panel.
2. Disable the SIR system.
3. Remove the connector (2) from the IP.
4. Remove the inflatable restraint IP module retaining bolts gripping the IP module firmly.
5. Remove the inflatable restraint IP module.
6. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required

retention period. refer to the Inflater Module Handling and Scrapping.

INSTALLATION PROCEDURE

1. Install the inflatable restraint IP module (1) to the mounting bracket through the front of the instrument panel.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the fasteners to the inflatable restraint IP module.

Tighten
Tighten the fasteners to 10 Nm (89 lb in).

3. Enable the SIR system.
4. Install the yellow connector (2) to the IP.
5. Install the upper IP trim panel.

Front Seat Side Impact Inflator Module Replacement