Chevrolet Workshop Service and Repair Manuals

A/T - Allison 1000, Fluid Leak from Pump Area|Page 8208 > < A/T - Allison 1000, Fluid Leak from Pump Area
Page 2
background image

2.

Remove the two lower torque converter housing bolts (1).

3.

Install the copper washer to each bolt and reinstall the bolts.

Tighten:

Tighten the torque converter housing bolts to 57 N.m (42 lb ft).

4.

Install the torque converter into the transmission.

 

Parts Information

Parts are currently available from GMSPO.

Warranty Information

For vehicles repaired under warranty, use the table.