Air Door Actuator / Motor: Description and Operation
HVAC Air Delivery/Temperature Control Circuit Description

The Electronic Climate Control (ECC) modules (front or rear) serves as an interface between the passenger and the air delivery system. The ECC
modules compares passenger selections with environmental conditions and will adjust air delivery accordingly.

The following air delivery modes are available:

-

Defrost

-

Blend

-

Floor

-

Bi-level

-

Panel

-

External air circulation

-

Internal air circulation

The ECC modules requires two voltage sources in order to operate. Voltage is available at all times through the RADIO fuse.

When the ignition switch is in the RUN position, voltage is available through the HVAC I fuse.

A path to ground for the ECC modules is provided to grounds G200/G410.

The ECC modules receives inputs from the following temperature sensors:

-

The inside air temperature sensor.
A fan located internally to the inside air temperature sensor housing continually draws passenger compartment air over the sensor increasing
accuracy of the temperature reading.
The HVAC I fuse applies voltage for the fan motor when the ignition switch is in the RUN position. A path to ground for the fan motor is provided
to ground G202.

-

The outside air temperature sensor.

-

The sun load temperature sensor.

-

The upper discharge air temperature sensor (front or rear).

-

The lower discharge air temperature sensor (front or rear).

The ECC modules will use the sensor information in order to determine how much airflow to the heater core is required and will adjust the air 
temperature valve accordingly. The air temperature valve is located internally to the heater core housing. The position of the air temperature valve is
reported to the ECC modules by the air temperature valve sensor and motor. The HVAC I fuse applies voltage for the air temperature valve sensor and
motor when the ignition switch is in the RUN position.

Operation of the air temperature valve sensor and motor is supported by the following circuits:

-

An 5 volt reference circuit.

-

An ground reference circuit.

-

An signal return path circuit.

-

An motor drive signal circuit.

The ECC modules will control the actuation of individual motors of the HVAC assembly in order to direct air to the appropriate outlets. The HVAC I
fuse applies voltage for the HVAC assembly when the ignition switch is in the RUN position. With voltage available the ECC modules will complete the
current path to ground.