chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Air Door Actuator / Motor, HVAC|Service and Repair > < Initial Inspection and Diagnostic Overview|Page 7042
Page 2
background image

Air Delivery Vacuum Distribution

Important

^

To avoid misdiagnosis, complete Chart #6: "Air Flow From Outlets is Incorrect," before beginning Vacuum Diagnosis.  See: Symptom Related
Diagnostic Procedures/Without A/C/Chart 6 Airflow From Outlet Is Incorrect

1. Check vacuum supply to Solenoid Box (black vacuum hose) while Engine is running.

^

Vacuum should be approximately 60 kPa (18 psi) with Engine running.

^

Vacuum should remain at approximately 60 kPa (18 psi) when Engine is turned "OFF."

2. Test each vacuum actuator by disconnecting the vacuum hose and applying vacuum directly to the actuator. Repair or replace as necessary.
3. Reconnect all vacuum and electrical connections. Run Engine and cycle through the operating modes of the Heater Control Assembly while

observing the vacuum actuators.
^

Check for vacuum to the vacuum actuators by noting vacuum actuator position. When vacuum is applied, the actuator will retract, refer to Air
Delivery Vacuum Distribution Table.

^

If a vacuum actuator retracts when it should not, replace the Heater Control Assembly.

^

If a vacuum actuator does not retract when it should, check for vacuum leaks, collapsed vacuum hoses or binding valves. If OK, replace the
Solenoid Box.

Air Door Actuator / Motor, HVAC|Service and Repair > < Initial Inspection and Diagnostic Overview|Page 7042