Lumina V6-191 3.1L VIN T MFI (1993)
Control Valve Assembly - View B.
CLEAN AND INSPECT:
-
Do not clean solenoids in solvent.
-
Air dry.
DISASSEMBLY
-
Shift solenoids and TCC solenoids are held in place with spring clips (see exploded view).
IMPORTANT: Some valves are under spring pressure. Cover the end of the bore when removing roll pins.
-
Valves, springs and bushings must be laid out on a clean surface exactly the way they were removed.
CLEAN:
-
All valves, springs, and bushings in solvent, then dry using compressed air.
INSPECT:
-
Shift solenoids and PWM solenoids for:
-
Cut O-ring.
-
Bent electrical connector or broken wire.
-
Cracked or damaged plastic housing.