INSPECT:
-
Shift solenoids and PWM solenoids for:
-
Cut O-ring.
-
Bent electrical connector or broken wire.
-
Cracked or damaged plastic housing.
-
Foreign material.
-
All valves and bushing for:
-
Wear.
-
Nicks.
-
Scratches.
-
Springs for damage or distorted coils.
-
Valves body casting for:
-
Porosity.
-
Interconnected oil passages.
-
Damaged machine surfaces.
-
Damaged pump shaft bearing.
ASSEMBLE
-
Valves, springs and bushings in the order that they came out.
-
Move the valves with a pick or small screwdriver to ensure that all assemblies move correctly.
Install Control Valve Body