16.

Attach the AIR pump and bracket assembly, and the vacuum solenoid, to the frame rail (using the original fasteners. Note: solenoid is attached at
the rear fastener location, over the bracket, and must be positioned vertically with the vacuum ports down and the splash cap up.

17.

Push the check valve and hose fully onto the TEE" hose coupling and clamp then push the outlet hose from the AIR pump fully onto the inlet of
the shut-off valve and clamp.

18.

Connect the short vacuum hose to the higher port on the solenoid, and to the vacuum port on the shut-off valve.

19.

Connect the vacuum supply harness to the bottom port on the vacuum solenoid.

20.

Connect the electrical wiring to the AIR pump, and close off the (unused) bleed solenoid connector using plug P/N 12064959. Tape bleed solenoid
connector to harness with electrical tape.