Lumina V6-3.1L VIN J (2000)
Air Door Actuator / Motor: Service and Repair
Defroster Actuator Replacement
REMOVAL PROCEDURE
1. Remove the right side instrument panel insulator.
2. Remove the instrument panel compartment.
3. Disconnect the vacuum lines (1) from the defroster vacuum actuator.
4. Released the defroster vacuum actuator retaining clip (2) from the HVAC module.
5. Rotate the air inlet vacuum actuator in order to disconnect the actuator shaft (3).
6. Remove the air inlet vacuum actuator from the module.
INSTALLATION PROCEDURE
1. Rotate the defroster vacuum actuator in order to connect the actuator shaft (3).
2. To install, align the actuator and press inward to engaged on the mounting tabs on the HVAC module (2).
3. Connect the vacuum lines (1) to the defroster vacuum actuator.
4. Install the instrument panel compartment.
5. Install the right side instrument panel insulator.