Condenser HVAC: Service and Repair

Condenser Mounting

Remove or Disconnect

1. Recover refrigerant. 
2. Air cleaner and duct assembly. 
3. Radiator. 
4. A/C lines at condenser.
5. Condenser.

Install or Connect

1. Condenser.
2. New O-ring seals on hose and pipe fittings coated with mineral base 525 viscosity refrigerant oil.
3. Liquid line fitting to condenser.

Tighten
^

Fitting to 27 N.m (20 lb. ft.).

4. A/C compressor line to condenser with mounting bolt.

Tighten
^

Bolt to 16 N.m (11 lb. ft.).

5. Radiator. 
6. Air cleaner and duct assembly. 
7. Evacuate, charge and leak test system. 