Lumina V6-3.8L VIN K (1998)
Condenser HVAC: Service and Repair
Condenser Mounting
Remove or Disconnect
1. Recover refrigerant.
2. Air cleaner and duct assembly.
3. Radiator.
4. A/C lines at condenser.
5. Condenser.
Install or Connect
1. Condenser.
2. New O-ring seals on hose and pipe fittings coated with mineral base 525 viscosity refrigerant oil.
3. Liquid line fitting to condenser.
Tighten
^
Fitting to 27 N.m (20 lb. ft.).
4. A/C compressor line to condenser with mounting bolt.
Tighten
^
Bolt to 16 N.m (11 lb. ft.).
5. Radiator.
6. Air cleaner and duct assembly.
7. Evacuate, charge and leak test system.