Variable Valve Timing Solenoid: Service and Repair

Camshaft Position Actuator Solenoid Valve Replacement

Removal Procedure

1. Remove the intake manifold cover.
2. Disconnect the engine wiring harness electrical connector (1) from the exhaust camshaft position (CMP) actuator solenoid valve (4), if required.
3. Disconnect the engine wiring harness electrical connector (2) from the intake CMP actuator solenoid valve (3), if required.

4. Remove the exhaust (1) CMP actuator solenoid valve bolt and valve, if required.
5. Remove the intake (2) CMP actuator solenoid valve bolt and valve, if required.
6. Inspect the solenoid valve O-ring seals for damage, replace as necessary.

Installation Procedure

Camshaft Position (CMP) Actuator Solenoid Valve (LZ4)|Page 4111 > < Camshaft Position (CMP) Actuator Solenoid Valve (LZ4)|Page 4109