Blower Motor: Customer Interest
A/C - Noise From HVAC in Cold/Cool Weather

TECHNICAL

Bulletin No.: 09-01-39-003A

Date: June 04, 2009

Subject: Whistle, Tone or High Pitched Hum Noise From HVAC in Cold/Cool Weather (Replace Blower Motor Control Processor)

Models:

2007-2009 Chevrolet Malibu
2007-2009 Pontiac G6 
2007-2009 Saturn AURA
All Equipped with Automatic HVAC (RPO C68)

 ................................................................................................................................................................................................................................................ 
Supercede:
This bulletin is being revised to add the Saturn AURA. Please discard Corporate Bulletin Number 09-01-39-003 (Section 01 - HVAC).

 ................................................................................................................................................................................................................................................ 

Condition

Some customers may comment on a tone, whistle or high pitched hum type noise when operating their vehicle in cold or cool weather with the Automatic
HVAC "On". The noise may be present while the vehicle is first warming up or after the interior has reached the requested temperature and the blower
speed is ramping down.

This condition can be verified by turning off the HVAC which will eliminate the whistle, if the HVAC is the source.

Cause

This condition may be caused by a resistor internal to the blower motor control processor that may be emitting the objectionable noise.

Correction

Replace the blower motor control processor following this procedure

1. Remove the right side I/P closeout panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side.
2. Disconnect the blower motor control processor wire harness connector.
3. Remove the blower motor control processor screws.

4. Remove the blower motor control processor.