Safety Disconnect Impact Sensor: Service and Repair

Generator Battery Disconnect Control Module Replacement

Removal Procedure

Caution:  To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal
components will still be live, 36V potential, even when the cover has been opened or removed
.

1. Disconnect the hybrid battery.
2. Remove the plastic nut (2) from the generator battery disconnect control module negative stud.
3. Remove the 36-volt negative battery cable lead (1) from the generator battery disconnect control module negative stud.

4. Remove the generator battery fuse (1) from the generator battery disconnect module negative stud.