10. Tighten the generator control module 3-phase cable terminal block nuts in the sequence shown.
Tighten the nuts to 8 N.m (71 lb in).
11. Place a NEW terminal block seal onto the generator control module.
12. Unsecure, and position the 36-volt terminal block (2) to the generator control module.
13. Install the 36-volt terminal block nuts (1) to the generator control module.