background image

5. Install the new blower motor control processor, GM P/N 20773421.
6. Tighten the blower motor control processor screws.

Tighten
Tighten the screws to 1.5 Nm (13 lb in).

7. Connect the blower motor control processor wire harness connector.
8. Install the right side I/P closeout panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side.