chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Heated Oxygen Sensor 1 Replacement|Page 2020 > < Heated Oxygen Sensor 1 Replacement|Page 2018
Page 2
background image

4. Remove the HO2S (1), if necessary use the J 39194.

Installation Procedure

Important:  A special anti-seize compound is used on the heated oxygen sensor threads. The compound consists of a liquid graphite and glass
beads. The graphite will burn away, but the glass beads will remain, making the sensor easier to remove. New or service replacement sensors
will have the compound applied to the threads. If a sensor is removed and is to be reinstalled, the threads must have an anti-seize compound
applied prior to installation.

1. If necessary, coat the threads of the HO2S with anti-seize compound GM P/N 12377953 or equivalent.

Notice:  Refer to Fastener Notice.

2. Install the HO2S (1), if necessary use the J 39194-C.

Tighten the sensor to 42 N.m (31 lb ft).

Heated Oxygen Sensor 1 Replacement|Page 2020 > < Heated Oxygen Sensor 1 Replacement|Page 2018