chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Sensors and Switches - Ignition System > < Diagram Information and Instructions|Page 1094
Page 3
background image

3. Install the 2 TP sensor fasteners, using a thread-locking compound on the screws. Loctite(R) 262, GM P/N #1052624., or equivalent should be

used.

Tighten
Tighten the TP sensor attaching screws to 2 N.m (18 lb in).

4. Connect the TP sensor electrical connector.

5. Install the air intake duct.

Sensors and Switches - Ignition System > < Diagram Information and Instructions|Page 1094