6. Reposition the surge tank outlet hose clamp at the surge tank using the J 38185.
7. Remove the surge tank outlet hose from the surge tank.
8. Remove the surge tank.
Installation Procedure
1. Install the surge tank outlet hose to the surge tank.
2. Reposition the surge tank outlet hose clamp at the surge tank using the J 38185.
3. Connect the coolant level sensor wire harness connector.
4. Tilt the surge tank and lead the weld seam on the surge tank under the ribs at the rear of the mounting bracket.
5. Press down on the surge tank to engage the mounting tabs.