chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Air Door Actuator / Motor, HVAC|Service and Repair > < HVAC System - Automatic|Page 7303
Page 1
background image

Air Door Actuator / Motor: Description and Operation

HVAC SYSTEM - MANUAL

AIR DELIVERY

Mode/Recirculation Actuator
The mode or recirculation actuator is a 2 wire bi-directional electric motor. Two control circuits enable the actuator to operate. The control circuits
use either a 0 or 12-volt value to co-ordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In
order to move the actuator, the HVAC control module grounds the appropriate control circuit for the commanded direction. The HVAC control
module reverses the polarity of the control circuits to move the actuator in the opposite direction.

The HVAC control module determines the door position by counting motor pulses on one of the control circuits. These pulses are small voltage
fluctuations that occur when the brush is shorted across 2 commutator contacts as the motor rotates. As the actuator shaft rotates, the HVAC control
module monitors the voltage drop across an internal resistance to detect the pulses. The HVAC control module converts the pulses to counts with a
range of 0 to 255 counts. The HVAC control module uses a range of 0-255 counts to index the actuator position.

AIR TEMPERATURE

Air Temperature Actuator
The air temperature actuator is a 2 wire bi-directional electric motor. Two control circuits enable the actuator to operate. The control circuits use either
0 or 12-volt value to co-ordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In order to move
the actuator, the HVAC control module grounds the appropriate control circuit for the commanded direction. The HVAC control module reverses the
polarity of the control circuits to move the actuator in the opposite direction.

The HVAC control module determines the door position by counting motor pulses on one of the control circuits. These pulses are small voltage
fluctuations that occur when the brush is shorted across 2 commutator contacts as the motor rotates.

HVAC SYSTEM - AUTOMATIC

AIR DELIVERY

Mode/Recirculation Actuator
The mode or recirculation actuator is a 2-wire bi-directional electric motor. Two control circuits enable the actuator to operate. The control circuits
use either a 0 or 12-volt value to co-ordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In
order to move the actuator, the HVAC control module grounds the appropriate control circuit for the commanded direction. The HVAC control
module reverses the polarity of the control circuits to move the actuator in the opposite direction.

The HVAC control module determines the door position by counting motor pulses on one of the control circuits. These pulses are small voltage
fluctuations that occur when the brush is shorted across 2 commutator contacts as the motor rotates. As the actuator shaft rotates, the HVAC control
module monitors the voltage drop across an internal resistance to detect the pulses. The HVAC control module converts the pulses to counts with a
range of 0-255 counts. The HVAC control module uses a range of 0-255 counts to index the actuator position.

AIR TEMPERATURE

Air Temperature Actuators
The air temperature actuator is a 2-wire bi-directional electric motor. Two control circuits enable the actuator to operate. The control circuits use
either a 0 or 12-volt value to co-ordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In order to
move the actuator, the HVAC control module grounds the appropriate control circuit for the commanded direction. The HVAC control module
reverses the polarity of the control circuits to move the actuator in the opposite direction. The HVAC control module determines the door position by
counting motor pulses on one of the control circuits. These pulses are small voltage fluctuations that occur when the brush is shorted across 2
commutator contacts as the motor rotates. As the actuator shaft rotates, the HVAC control module monitors the voltage drop across an internal
resistance to detect the pulses. The HVAC control module converts the pulses to counts with a range of 0-255 counts. The HVAC control module uses
a range of 0-255 counts to index the actuator position.

Air Door Actuator / Motor, HVAC|Service and Repair > < HVAC System - Automatic|Page 7303