Ambient Temperature Sensor / Switch HVAC: Description and Operation

AIR TEMPERATURE

Air Temperature Sensors
The air temperature sensors are 2-wire negative temperature co-efficient thermistors. The vehicle uses the following air temperature sensors:
-

Ambient

-

Inside

-

Upper duct air temperature sensor

-

Lower duct air temperature sensor

A signal and low reference circuit enables the sensor to operate. As the air temperature surrounding the sensor increases, the sensor resistance
decreases. The sensor signal decreases as the resistance decreases. The sensor signal varies between 0-5 volts. The HVAC control module converts
the signal to a range between 0-255 counts.

The inside air temperature sensor is located within the HVAC control module. Replacement of this sensor involves the replacement of the HVAC
control module. The inside air temperature sensor operates within a temperature range between -40 to +185°C (-40 to +365°F). If the sensor is
shorted to ground, voltage, or an open, the system will operate using an estimated default value to allow the system to operate. The ambient
temperature sensor operates within a temperature range between -40 to +87.5°C (-40 to +189.5°F). The sensor signal is read by the BCM, scaled
appropriately and transmitted to the HVAC Control Module through the Low Speed bus.If the sensor is shorted to ground, voltage, or an open, the
system will operate using a signal scaled appropriately to allow the system to operate.

The duct temperature sensor temperature response is different from the ambient and inside sensors. A signal and low reference circuit enables the
sensor to operate. As the air temperature surrounding the sensor increases the sensor resistance decreases. The sensor operates within a temperature
range between -40 to +80°C (-40 to +176°F).