chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Pedal Positioning Sensor|Locations|Page 810 > < Pedal Positioning Sensor|Locations|Page 808
Page 1
background image

Pedal Positioning Sensor: Description and Operation

BRAKE PEDAL POSITION SENSOR CALIBRATION DESCRIPTION AND OPERATION

CALIBRATION CRITERIA

The brake pedal position sensor receives a low reference signal and a 5-volt reference signal from the BCM. Whenever the brake pedal is applied, the
brake pedal position sensor applies a variable voltage signal to the BCM through the stop lamp switch signal circuit. Brake pedal position sensor
calibration must be performed after the brake pedal position sensor or body control module (BCM) have been serviced. The calibration procedure will
set brake pedal position sensor home value. This value is used by the BCM to determine the action of the driver applying the brake system and to
provide this information to the vehicle subsystems via the class 2 communication bus.

CALIBRATION PROCEDURE

-

Install a scan tool.

-

Turn ON the ignition, with the engine OFF.

-

Select Diagnostics.

-

Select the vehicle.

-

Select Body and Accessories.

-

Select Lighting Systems.

-

Select Special Functions.

-

Select BCM.

-

Select the BPPS sensor calibration procedure and follow the directions displayed on the screen.

Pedal Positioning Sensor|Locations|Page 810 > < Pedal Positioning Sensor|Locations|Page 808