18. Connect the RF brake pipe fitting (1) and tighten to 20 Nm (15 lb ft).
Note: Ensure the electrical connector is correctly inserted into the EBCM prior to placing the locking lever into position. Failure to make a proper
connection may cause communication problems with the module.
19. Connect the EBCM electrical connector.
20. Install the radiator surge tank. Refer to Radiator Surge Tank Replacement (See: Engine, Cooling and Exhaust/Cooling System/Coolant
Reservoir/Service and Repair/Radiator Surge Tank Replacement).
21. Bleed the hydraulic brake system. Refer to Hydraulic Brake System Bleeding (See: Brake Bleeding/Service and Repair/Hydraulic Brake System
Bleeding).
22. Calibrate the brake pedal position sensor. Refer to Brake Pedal Position Sensor Calibration (See: Accessories and Optional Equipment/Pedal
Positioning System/Pedal Positioning Sensor/Service and Repair/Brake Pedal Position Sensor Calibration).