Malibu V6-3.6L (2010)
Variable Valve Timing Solenoid: Service and Repair
Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Intake
Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Intake
Removal Procedure
1. Remove the engine mount snubber bracket. Refer to Engine Mount Snubber Bracket Replacement (See: Drive Belts, Mounts, Brackets and
Accessories/Engine Mount/Service and Repair/Engine Mount Snubber Bracket Replacement).
2. Disconnect the engine wiring harness electrical connector (2) from the bank 2 intake camshaft position (CMP) actuator solenoid valve.
3. Remove the CMP actuator solenoid valve bolt.
4. Remove the CMP actuator solenoid valve.
5. Inspect the CMP actuator solenoid valve seal for damage and replace as necessary.
Installation Procedure