Removal Procedure

1. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement   (See: Fuel Delivery and Air Induction/Air Cleaner

Housing/Service and Repair).

2. Remove the engine mount snubber bracket. Refer to Engine Mount Snubber Bracket Replacement   (See: Engine, Cooling and

Exhaust/Engine/Drive Belts, Mounts, Brackets and Accessories/Engine Mount/Service and Repair/Engine Mount Snubber Bracket Replacement).

3. Disconnect the engine wiring harness electrical connector (4) from the bank 2 exhaust camshaft position (CMP) actuator solenoid valve.

4. Remove the CMP actuator solenoid valve bolt.
5. Remove the CMP actuator solenoid valve.
6. Inspect the CMP actuator solenoid valve seal for damage and replace as necessary.