Fluid Pump: Service and Repair

Oil Pump Replacement

Removal Procedure

1. Remove the case side cover.
2. Use a flat-bladed tool to disconnect the electrical connectors from the solenoid valves (315A, 315B, 322, 334 and 440), the TFP manual valve

position switch (395) and the temperature sensor (391).

Important:  Do NOT remove the bolt (205) that holds the oil pump together.

3. Remove the oil pump bolts (206, 207).

4. Remove the oil pump (200) from the valve body (300).
5. Inspect the oil pump.

Installation Procedure