Metro L3-061 1.0L VIN 6 TBI (1998)
Blower Motor: Service and Repair
Removal Procedure
1. Remove the powertrain control module.
2. Disconnect the blower motor and the blower motor resistor electrical connectors.
3. Disconnect the fresh/recirc control cable (3) from the blower case (4).
4. Remove the 3 bolts (1).
5. Remove the blower case from the vehicle.
6. Disconnect the air hose between the. blower motor and the blower case.
7. Remove the 3 screws (1) and the blower motor (3) from the blower case.