chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Relays and Modules - HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Locations
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

1.

Disconnect negative battery cable. Under normal conditions, it is not necessary to discharge system refrigerant during this procedure, as 
switch unit fitting is supplied with a Schrader valve.

2.

Disconnect switch harness connection. Unscrew unit from accumulator.

3.

When installing new switch unit, install new oiled O-ring and torque switch to 7.5 ft. lbs. Be careful not to over tighten switch.

4.

Reconnect harness and battery cable. 

Relays and Modules - HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Locations