chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

BCM - Related Service. Theft Deterrent Relearn|Page 11341 > < BCM - Related Service. Theft Deterrent Relearn
Page 2
background image

THIS MEANS THAT THE TECH 2 HAS SET THE BCM TO ACCEPT THE CORRECT INFORMATION. THIS IS NOT THE END OF THE
PROGRAMMING PROCEDURE.

9.

Exit back to the Special Functions menu.

10.

Select Set Options.

11.

Input all of the required data as prompted by the Tech 2.

12.

Exit back to the Special Functions menu.

13.

Select Option Configuration.

14.

Input all of the required data as prompted by the Tech 2.

15.

When the BCM, VIN, Point of Sale and option configuration have been entered, proceed with the Theft Deterrent Re-Learn Procedure.

IF THE TECH 2 DISPLAYS "UNABLE TO PROGRAM THE BCM", THE BCM IS LOCKED. TWENTY KEY CYCLES HAVE OCCURRED
SINCE THE MODULE WAS INSTALLED AND VOLTAGE WAS SUPPLIED TO THE MODULE SO THE MODULE MUST BE REPLACED
AND THIS PROCEDURE MUST BE REPEATED IN ITS ENTIRETY.

Important: 

Programming of the BCM removes any personalization settings the customer may have previously set. Inform the customer the personalization
settings will have to be reset.

Theft Deterrent Re-Learn

Important: 

Perform the Theft Deterrent Re-Learn Procedure when one or more of the following conditions has occurred.

-

The BCM has been replaced or re-programmed (Set-up) (Configured).

-

The ignition key cylinder assembly has been replaced.

The Theft Deterrent Re-Learn Procedure can be accomplished two different ways depending on the equipment you have available.

^

Using The Techline equipment and the Tech 2 scan tool.

^

Without Techline Equipment of any kind. This procedure takes 30 minutes and must not be shortened.

USING TECHLINE EQUIPMENT AND THE TECH 2 SCAN TOOL

1.

If you disconnected the scan tool from the DLC, perform the following 3 steps. If it is still connected, proceed to step 5.

2.

Ensure that the key (or ignition) switch is in the LOCK position with the ignition off.

3.

Connect the Tech 2 scan tool to the Data Link Connector (DLC).

4.

Turn the key to the ON position.

5.

From the Main Menu screen of the Tech 2, select Service Programming.

6.

Enter the requested information.

7.

Select Request Info.

8.

When the Tech 2 finishes gathering the information, disconnect the Tech 2 from the DLC.

9.

Connect the Tech 2 to the Techline terminal.

10.

Select Service Programming System (SPS).

11

Select Terminal to Tech 2 programming.

12.

Select Done.

BCM - Related Service. Theft Deterrent Relearn|Page 11341 > < BCM - Related Service. Theft Deterrent Relearn